Milano RAD Store

The download centre · NextRad Workstation V3

Your workstation.
Your workflow.

Current V3 core updates support Apple silicon Macs, Windows x64 and Linux x64. Add specialist plug-ins and Local AI as you need them. Specialty access depends on your licence and installed plug-ins.

v— Preview channel 30-day trial · no card
Loading installers…
Verify SHA-256 checksums for every core installer
  • Loading…

ATLAS STUDIO · NEW

Turn handwriting and drawings into professional AI-assisted lectures.

Polished teaching diagrams, annotated synthetic imaging, and PDF / PowerPoint lectures. Works with your Gemini API key or external Gemini Web.

Apple Silicon · Intel Mac · Windows 64-bit · Seven-day trial

02 · Make it yours

Specialist plug-ins

Signed packages install from Settings → Plug-ins on any supported system. Your licence decides what each one unlocks.

How to install ↓

Cinematic 3D Rendering

Photorealistic volume rendering with lighting, tissue colours and cine export. Organ masks come from Local AI.

  • WebGPU renderer
  • Organ masks: Local AI
  • Windows · macOS · Linux

Core 3.0.69+ · AI setup

Loading…

Film / Print Station

Film layouts, image adjustments, preview and PDF composition for DICOM film printers and paper.

  • Runs in core
  • Windows · macOS · Linux

Core 3.0.67+

Loading…

Stitching & Long-Bone

Full-resolution X-ray stitching for long-leg and full-spine runs, PET-CT whole body and multi-station MRI.

  • Runs in core
  • Windows · macOS · Linux

Core 3.0.69+

Loading…

Dental & CBCT

Cephalometric tracing and crown–root ratio; on CBCT, 3D length and angle, implant and endodontic planning, a lateral ceph and airway analysis.

  • Runs in core
  • Windows · macOS · Linux

Core 3.0.68+

Loading…

Ortho & Spine Suite

Cobb angles and sagittal balance, pelvic parameters, leg-length discrepancy and lower-limb alignment, with calibration.

  • Runs in core
  • Windows · macOS · Linux

Core 3.0.68+

Loading…

CSF Flow Dynamics

Phase-contrast CSF flow: velocity and flow curves through a drawn region.

  • Runs in core
  • Windows · macOS · Linux

Core 3.0.68+

Loading…

Vascular & Angio Analysis

Vessel extraction for CT angiography. Standard extraction runs in the core; a precise AI extraction is added by Local AI.

  • Standard: in core
  • Precise AI: Local AI
  • Windows · macOS · Linux

Core 3.0.69+ · AI setup

Loading…

Cardiac CT, MRI & LGE Review

Coronary CT, calcium, chambers and cine MRI function, with AI cine contours, T2* tools and manual LGE segment grading. Automated scar quantification is in development.

  • AI cine contours: Local AI
  • Windows · macOS · Linux

Core 3.0.84+ · Research use, not for diagnosis · Test cases

Loading…

Iron Overload (MRI T2*)

Heart and liver T2* / R2* from multi-echo GRE, with liver and myocardial iron (LIC, MIC) from published calibrations.

  • Runs in core · no AI
  • Windows · macOS · Linux

Core 3.0.86+ · Research use, not for diagnosis · Test cases

Loading…
Local AI

Local AI

Local AI runtime and model setup for Cinematic, Vascular and Cardiac tools.

  • Runs on your computer

Reporting

Local report editor with templates, PDF export and a verification workflow, launched from a licensed Workstation.

  • Companion app
  • Windows · macOS · Linux

Installs beside the Workstation

Loading…

Auto-Import Watchdog

Imports DICOM from inserted USB sticks and CDs, and from watched folders.

  • Companion app
  • Windows · macOS · Linux

Installs beside the Workstation

Loading…

CD/DVD Burner + Viewer

A DICOM node that burns patient CDs and DVDs with an embedded viewer.

  • Companion app
  • Windows · macOS · Linux

Installs beside the Workstation

Loading…

Breast Imaging & Mammography

One package for mammography, breast MRI and ultrasound: structured findings, BI-RADS assessment, kinetic curves and reporting. Requires the Breast licence entitlement.

  • Runs in core
  • Windows · macOS · Linux

Core 3.0.86+ · Research use, not for diagnosis

Loading…

Neuro Suite

Neuro measurements and planning, with brain segmentation and tractography interfaces. AI workflows require a compatible local runtime and models.

  • Runs in core
  • Windows · macOS · Linux

Core 3.0.69+ · Research use, not for diagnosis

Loading…

Virtual Scope

Local CT lumen navigation with routes, linked MPR, measurements and cine export.

  • Runs in core
  • Windows · macOS · Linux

Core 3.0.72+ · Research use, not for diagnosis

Loading…

Anal Canal Assessment

MRI defecography and dynamic perianal / transperineal ultrasound. Review phases, edit measurements and prepare readable reports locally.

  • Runs in core
  • Windows · macOS · Linux

Core 3.0.86+ · Research use, not for diagnosis

Loading…
Installing or updating a plug-in

Open Settings → Plug-ins → Install signed update, choose the downloaded .nrplugin file and restart the Workstation. Plug-ins can be enabled, disabled or rolled back there without a new core.

Signed packages work on every supported Windows, macOS and Linux host, x64 and ARM64. Companion apps (Reporting, CD Burner, Auto-Import) and Local AI use their own system installer.

03 · Process locally

Local AI engine

Adds AI segmentation to Cinematic, Vascular and Cardiac. Models run on your machine; images never leave it.

Online setup ≈ 203 MB + ≈ 2.2 GB of runtime packages and models

Loading installer…

The public installer is for Windows x64. On macOS and Linux, point Local AI at a compatible local Python runtime.

Cardiac MRI AI model pack ≈ 1.2 GB · Windows, macOS, Linux · core 3.0.85+

Loading…

Unzip it and run the installer for your system; it checks every file and links the model to Local AI. Signed UK Biobank nnU-Net weights (CC0). Research use, not for diagnosis.

  1. Install the Workstation core
    Install NextRad Workstation V3 from the top of this page, plus the plug-in you want to use (Cinematic, Vascular or Cardiac).
  2. Download the Local AI runtime
    Windows x64: run the online setup above. It fetches the runtime and models (≈ 2.2 GB). macOS / Linux: prepare a compatible local Python runtime.
  3. Configure it in Settings
    Open Settings → Plug-ins → Local AI, enable it and run the runtime check. Auto picks a compatible GPU first and falls back to CPU; GPU only reports an error when none is available.
  4. Run inference from the tool
    Start segmentation from Cinematic, Vascular or Cardiac (cine MRI). Saved masks stay viewable without running the model again.
Which workflows need Local AI, and with which model
WorkflowModel / engineAccelerationLocal AI
Cinematic renderingWebGPU rendererGPUNot required
Cinematic organ segmentationTotalSegmentatorCUDA · Apple Metal · CPURequired
Vascular standard extractionLocal vessel extractionCPUNot required
Vascular precise AITotalSegmentatorCUDA · Apple Metal · CPURequired
Cardiac cine MRI contoursnnU-Net v2 · UK Biobank SAX (model pack)CUDA · Apple Metal · CPURequired
Neuro brain segmentation Local setup requiredSynthSegGPU or CPURequired
Neuro tractography Local setup requiredDIPY (Diffusion Imaging in Python)CPURequired

04 · Recommended computer

Hardware & systems

Suggested configurations for the best experience, not minimums or guaranteed processing times.

Processor
Modern 8-core Intel or AMD
Memory
32 GB64 GB for whole-body CT/MRI and tractography
GPU
NVIDIA, 12 GB VRAM or more16 GB preferred for larger models; CUDA runtime for AI
Storage
NVMe SSD, 1 TB suggestedKeep at least 100 GB free for models, caches and exports
Display
1920 × 1080 or higher2560 × 1440 suits a 27-inch screen
Systems
Windows 10 / 11 x64Ubuntu 24.04+ x64.

Windows ARM GPU inference is not verified. CPU fallback works with a compatible runtime but takes longer.

05 · On the horizon

In development

In development

Automated Cardiac LGE & Mapping

Automated scar quantification and T1 / T2 mapping are in development. The available Cardiac plug-in includes manual LGE segment grading and T2* tools.

In development

Broker & HL7 Watch Folder

HL7 .hl7 / .txt and Paxera .txt / .rep parsing.

06 · Explore

Cases to get started

NextRad V3 demo package

Version 1.0.0 · 3,203 DICOM instances · DTI covers a limited parietal slab · facial anatomy removed from the brain study · no cephalometry or CBCT.

Spine MRIX-ray stitchingPET/CTCT angiographyBrain MRI / DTI
69e5f8bf09f58cf492b08b46028a71b897f5b964cc2fe73f894c62810c24c614
Download demo cases297 MB ↓

Public cardiac test cases

Links to public research datasets for trying the Cardiac and Iron plug-ins. The cardiac CT sources are NIfTI / NRRD, so convert them to DICOM first. They are not hosted here: download from the source, under its own terms, and cite it as it asks. For testing and evaluation, not diagnosis.

Cardiac CT · coronary CTA

ImageCAS coronary CT angiography

1,000 adult coronary CTAs (ECG-gated acquisitions, one reconstructed phase, no RR timing) with expert coronary-artery labels. NIfTI: convert to DICOM before importing. CC BY-NC 4.0, non-commercial research and education; the images are on Kaggle (free account).

Zeng A et al. Comput Med Imaging Graph 2023;109:102287 · ImageCAS authors

Open source pagegithub.com ↗
Cardiac CT · 4D multiphase

SlicerHeart cardiac CT test data

A 4D cardiac CT with 21 phases (truncal valve, 1.3 GB) and a single-phase structural CTA (55 MB). Phase indices only, no ECG timing. NRRD: convert to DICOM (for example in 3D Slicer) before importing.

SlicerHeart project, public TestingData release on GitHub

Open source pagegithub.com ↗
Cardiac MRI · short-axis cine

Sunnybrook Cardiac Data

45 SSFP cine short-axis studies with expert LV contours. DICOM in five batches of 0.4–0.8 GB. Public domain (CC0), direct download, no account.

Radau P, Lu Y, Connelly K, Paul G, Dick AJ, Wright GA. MIDAS J 2009, hdl:10380/3070 · Cardiac Atlas Project

Open source pagecardiacatlas.org ↗
Cardiac MRI · short- and long-axis cine

STACOM 2011 motion-tracking data

15 healthy volunteers: SSFP cine in short-axis, 2- and 4-chamber views, plus 3D tagging. DICOM, about 0.3–0.6 GB per case. Open access with attribution.

Tobon-Gomez C et al. Med Image Anal 2013;17:632–648, doi:10.1016/j.media.2013.03.008 · Cardiac Atlas Project

Open source pagecardiacatlas.org ↗
Cardiac & liver MRI · multi-echo T2*

CHMMOTv1 iron-overload dataset

124 thalassaemia patients, 12-echo GRE of the mid-ventricular heart and the liver, with reference T2* values. DICOM (one archive linked from the record). CC BY 4.0.

Abedi I, Zamanian M, Bolhasani H, Jalilian M. Mendeley Data V1, doi:10.17632/3d8bwn2fsh.1

Open source pagedata.mendeley.com ↗

07 · Infrastructure

Core utilities & connectivity

The viewer on its own, reporting, and the services that connect sites to a PACS.

NextRad Standalone Viewer

The viewer alone: local DICOM folders and any DICOMweb server, as a desktop app or a PACS web build.

—

Loading…

Reporting Station

Standalone reporting: worklist by QIDO / C-FIND or HL7, signed PDFs back to the PACS.

—

Loading…

DICOM Broker & Worklist Bridge

Modality worklist server and RIS bridge for the modalities on site.

—

Loading…

DICOM Uploader

Sends studies from a site to the cloud PACS.

—

Loading…

Patient Web Portal

Patients view and download their studies and reports. Linux build upcoming.

—

Loading…

DICOM Router & Forwarder

Receives studies and forwards them between DICOM nodes. Linux build upcoming.

—

Loading…

DICOM Broker (C#)

The Broker built for Windows in C#. Linux build upcoming.

—

Loading…

Details